Computer Automation Technology
Fort Lauderdale, Florida
CAT Note
11
Release Date: March 10, 2004
Connecting a CAT to a Vertex-7000 Repeater

Connecting a CAT controller to a Vertex-7000 Repeater can be accomplished easily by following these two steps.


Step 1
Build an interconnect cable with a DB25 male connector on both ends of a 5-wire conductor cable. Connect the connector pins as follows: (Note: a pre-built cable is available for purchase under CAT part number CA-7000).

FUNCTION
CAT controller
VXR-7000
NOTES
 Signal and Logic Grounds  Pin 17  Pin 14  
 Receiver COR #1  Pin 6  Pin 11  Signal goes low with a COR
 Receiver Audio  Pin 13  Pin 6  RX audio to CAT controller
 Transmitter Audio  Pin 11  Pin 3  TX audio from CAT controller
 PTT  Pin 10  Pin 12  VXR-7000 Transmitter Control


Step 2
Program the VXR-7000 repeater using the configuration software supplied with the repeater.

PARAMETER
CONFIGURED AS
 Frequency  Required RX and TX frequency pair
 Timers  All disabled
 Action Mode  Duplex
 DC Lowpower  Low Power
 Thermal Power Cont  Enabled
 Beep  Disabled
 Hang Time Mode  Quiet
 CTCSS  All OFF


Notes:
1. Set all VXR-7000 control switches to default position.
2. VXR-7000 Repeater/Base switch to Base position (Green lamp off).
3. VXR-7000 Remote/Local switch to Remote position (Green lamp on).

 

This site is best viewed with Internet Explore 5.0 and above or Netscape 6.0 and above.

Computer Automation Technology, Inc.
4631 N.W. 31st Avenue, Suite 142
Fort Lauderdale, Florida 33309

Main Office Number

Send mail to Webmaster with questions or comments about this web site.